Refrigeration Equipment

Cold Rooms

Cold rooms are insulated, panelled enclosures fitted with dedicated refrigeration systems to hold produce, meat, dairy, pharmaceuticals or other temperature-sensitive stock at a controlled chill or freeze temperature. Frosten designs, supplies and installs walk-in cold rooms sized from small back-of-house chillers to large-scale distribution and processing facilities.

Key Features

Insulated Panel Construction

PU/PIR sandwich panels in 60–150mm thickness depending on chill or freeze duty.

Heavy-Duty Construction

Reinforced flooring options for forklift and pallet-truck traffic.

Digital Temperature Control

Electronic controllers with high/low alarms and data logging.

Corrosion-Resistant Finishes

Food-grade, washable panel and door surfaces for hygiene compliance.

Modular Panel System

Rooms can be extended or reconfigured without full rebuild.

Benefits

  • Purpose-built temperature range for the specific stock being stored
  • Modular panels allow future expansion as storage needs grow
  • Digital monitoring and alarms protect stock value from temperature excursions
  • Custom sizing from small back-of-house rooms to full distribution facilities

Typical Applications

  • Supermarkets
  • Restaurants & Hotels
  • Pharmaceutical Storage
  • Flower & Produce Export
  • Meat & Dairy Processing
  • Cold Chain Distribution Centres

Available Capacities

  • 6–20 m³ (back-of-house chiller)
  • 20–100 m³ (medium storage room)
  • 100+ m³ (distribution / processing facility)

Optional Accessories

  • PVC strip curtains for door openings
  • Shelving and racking systems
  • Data logging and remote alarm systems
  • Door heater strips (freezer rooms)
  • Floor drainage and defrost water management

Available Models

Bitzer 2 HP R404A Condensing Unit

Manufacturer: Bitzer. 2 HP condensing unit for R404A refrigeration systems. From KES 350,000. Supplied and installed by Frosten as part of a cold room refrigeration package. Request Quotation

Brands We Supply

Daikin logo
Carrier logo
Hitachi logo

Installation Options

  • Insulated panel assembly on prepared, level flooring
  • Refrigeration plant mounted externally or in adjacent plant space
  • Electrical, control wiring and alarm system installation
  • Door and access point positioning for workflow efficiency

Preventive Maintenance

  • Door seal and hinge inspection monthly
  • Evaporator coil defrost check and cleaning quarterly
  • Condensing unit coil cleaning every 3–6 months
  • Temperature controller calibration and alarm test every 6 months
  • Panel joint and insulation integrity check annually

Warranty

Refrigeration plant warranty of 1–3 years depending on brand; panel and construction workmanship warranty from Frosten.

Industries Served

  • Food Processing
  • Retail & Supermarkets
  • Healthcare
  • Hospitality
  • Agriculture & Export

Typical Project Cost

From KES 400,000

This is Frosten's published starting rate for a full cold room / freezer room design-and-build. It covers a basic panel room with a dedicated refrigeration system; your final quotation depends on:

  • Room size and volume
  • Chill vs. freeze temperature
  • Panel type and insulation thickness
  • Refrigeration system capacity
  • Flooring and door specification
  • Electrical requirements
  • Site access and building type
  • Commissioning

Indicative costs vary according to site conditions and equipment selection, and final pricing is confirmed after we assess your installation requirements. Request a free quotation for a project-specific price. For a full breakdown of what drives the price, see our guide to cold room installation cost in Kenya.

Why Choose Frosten

Professional Installation

100% in-house delivery, no subcontractors, from design through commissioning.

Preventive Maintenance

Documented maintenance plans sized to your equipment and site.

Genuine Spare Parts

Parts sourced through authorised brand channels, not grey-market substitutes.

Qualified Technicians

Trained, accountable in-house engineers, the same team from survey to aftercare.

Fast Response

24/7 breakdown response across our service footprint.

Warranty Support

Manufacturer warranty backed by Frosten's own workmanship guarantee.

Frequently Asked Questions

What temperature range can a cold room hold?

Chill rooms typically hold 0–5°C for fresh produce, dairy and general chilled stock, while freezer rooms hold -18°C to -25°C for frozen goods; the panel thickness and refrigeration plant are sized to the target temperature.

Can an existing cold room be expanded?

Yes, modular panel construction allows a room to be extended, provided the refrigeration plant is upsized to match the additional volume and load.

How long does cold room installation take?

A standard back-of-house room can be installed in a few days; larger distribution facilities are scheduled around a full design and fabrication programme discussed at quotation stage.

Interested in Cold Rooms? Get a free quotation.